Axis T81B22 Guía de instalación Pagina 1

Busca en linea o descarga Guía de instalación para Adaptadores Poe Axis T81B22. Axis T81B22 Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 12
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
INSTALLATION GUIDE
ENGLISH
AXIS T81B22 DC 30W Midspan
Vista de pagina 0
1 2 3 4 5 6 ... 11 12

Indice de contenidos

Pagina 1 - AXIS T81B22 DC 30W Midspan

INSTALLATION GUIDEENGLISHAXIS T81B22 DC 30W Midspan

Pagina 2 - Japan

Page 10 AXIS T81B22 DC 30W MidspanTroubleshootingSymptom Corrective stepsMidspan does not power up1. Verify that the voltage at the power inlet is eit

Pagina 4 - Liability

Installation Guide Ver.1.0AXIS T81B22 DC 30W Midspan Printed: March 2012© Axis Communications AB, 2012 Part No. 46921

Pagina 5 - AXIS T81B22 DC 30W

About this DocumentThis document includes instructions for installing AXIS T81B22 on your network. Previous experience of networking will be beneficia

Pagina 6 - Installation

SafeguardsPlease read through this Installation Guide carefully before installing the product. Keep the Installation Guide for further reference.Cauti

Pagina 7 - Power Selector

LiabilityEvery care has been taken in the preparation of this document. Please inform your local Axis office of any inaccuracies or omissions. Axis Co

Pagina 8 - Mounting instructions

AXIS T81B22 DC 30W Midspan Page 5ENGLISHAXIS T81B22 DC 30W MidspanThe AXIS T81B22 DC 30W Midspan injects 51V DC power into the spare pairs of the Ethe

Pagina 9 - Specifications

Page 6 AXIS T81B22 DC 30W MidspanInstallation1. Set the Power Selector to the correct setting (15/30W).2. Connect the AXIS T81B22 to a DC limited powe

Pagina 10 - Troubleshooting

AXIS T81B22 DC 30W Midspan Page 7ENGLISHPower SelectorImportant!Before the unit is powered on, the power selector must be set in the correct position.

Pagina 11

Page 8 AXIS T81B22 DC 30W MidspanMounting instructionsThe AXIS T81B22 may be wall or bench mounted using the rear side holes. It can also be mounted o

Pagina 12 - Installation Guide Ver.1.0

AXIS T81B22 DC 30W Midspan Page 9ENGLISHSpecificationsEnvironmentalElectrical Ethernet interfaceMode Temperature HumidityOperating -20 to 65°C -4 to 1