Axis A1001 Guía de instalación Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 38
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
AXISA1001NetworkDoorController
AuxiliaryConnector
4-pincongurableI/Oterminalblockfor:
Auxiliarypower(DCoutput)
DigitalInput
DigitalOutput
0VDC(-)
Foranexampleconnectiondiagram,seeConnectionDiagrams,on
page21.
FunctionPinNotes
Specications
0VDC(-)
1
0VDC
DCoutput
2
Forpoweringauxiliaryequipment.
Note:Thispincanonlybeusedas
powerout.
3.3VDC
Maxload=100mA
DigitalinputConnecttopin1to
activate,orleaveoating(unconnected)
todeactivate.
0tomax40VDC
Congurable
(Inputor
Output)
3–4
DigitaloutputConnectedto
pin1whenactivated,oating
(unconnected)whendeactivated.If
usedwithaninductiveload,e.g.arelay,
adiodemustbeconnectedinparallel
withtheload,forprotectionagainst
voltagetransients.
0tomax40VDC,open
drain,100mA
PowerConnector
2-pinterminalblockforDCpowerinput.UseaSafetyExtraLowVoltage
(SELV)compliantlimitedpowersource(LPS)witheitheraratedoutput
powerlimitedto100Woraratedoutputcurrentlimitedto5A.
WhenusedinsystemsthatrequireULcertication,theproductshall
bepoweredbyaUL294-listedorUL603-listedClass2low-voltage
powerlimitedpowersupply.
19