Axis Q6035-C Guía de instalación Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 26
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Page 12 AXIS Q6032-C/Q6034-C/Q6035-C Installation Guide
Multi-Connector Cable
The supplied multi-connector cable is required in order to maintain the camera’s IP rating.
Connect the multi-connector cable to the camera’s multi-connector and to the
connectors in the supplied media converter switch, see illustrations on page
page 6 and page 8. The cable provides the following signals:
•DC power
•Network (Ethernet 10/100Base-T)
•I/O
Function Pin Wire Notes Specifications
Configurable
(Input or
Output)
2, 7 Blue, yellow Digital input – Connect to GND to activate, or
leave floating (unconnected) to deactivate.
0 to +30 V DC
Digital output – Internal connection to ground
when activated, floating (unconnected) when
deactivated. If used with an external relay, a
diode must be connected in parallel with the
load, for protection against voltage transients.
Max load =100 mA
Max voltage =
+30 V DC
RX+ 3 Green/white Ethernet – receiving
RX- 4 Green Ethernet – receiving
TX+ 5 Orange/white Ethernet – transmitting
TX- 6 Orange Ethernet – transmitting
GND 8 Black Ground
12 V Power 1, 9 Red Used to power camera 12 - 13.2 V DC
Max load = 6 A
1 8
2 7
9
3 6
4 5
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 25 26

Comentarios a estos manuales

Sin comentarios