AXIS Camera Station Administration
30 AXIS Camera Station User’s Manual
Example 1: Maximum alarm event time - Input
Example 2: Maximum alarm event time - Output
Defining an alarm event as an Input or Output is described inInput/Output, on page 38
Images to start/stop
alarm
Recording starts when motion is detected or an external alarm is triggered. By
setting the Images to start/stop alarm, it is possible to set how many images
with no action/alarm should pass before the event ends and the server returns
to its "normal" state.
When using the Alarm when motion stops option, set the number of images
with no motion allowed before the event triggers and recording is started. This
can help reduce unnecessary triggering for only very slight changes.
Event time = 5 minutes means that an
input event will time-out after 5 minutes.
If the maximum time is reached but motion is still
is created and recording continues.
detected at an input, a new alarm event
Event time = 5 minutes means that an
output event will time-out after 5 minutes
and recording will stop.