www.baldormotion.com
4-30 Input / Output MN1941
4.8 Connectio n summary - minimum wiring (local axis)
As a guide, Figure 31 shows an example of the typical minimum wiring required to allow the
NextMove e100 and a single axis servo amplifier to work together . Details of the connector pins
are shown in Table 2.
Servo amplifier
(axis 0)
Encoder output from
drive (or motor)
Gnd
Enable
Demand -
Demand +
Host PC
+24 V
control
supply
+24V
0V
X13
X5
X1
NextMove e100
1
2
3
9
10
X12
Common
earth/ground
USB connection
USB
Figure 31 - Example minimum system wiring