ADT Model 7100 Semi-Automatic Dicing System Operations Manual
Main Subsystems
P/N 97100-9002-000-14 Ver 06/05
2.1-3
In systems with Autoloader, the Stop button behaves the same way as in
a standard system. Upon Stop confirmation (the second press), the system
becomes idle, while the Autoloader performs initiation. All buttons are
disabled until the Autoloader initiation is completed.
If the Stop button is pressed, while the system is in Auto Run mode, the
system finishes the current process and brings the workpiece to the
manual unload station. The user is prompted to manually unload the
workpiece. In order to return to the Auto Run mode, press Auto Run.
The Stop button parameters can be defined under Cutting Block station
(see
Figure 2-3).
The system can be also stopped by clicking the stop icon on the screen
(see section 2.2.9).
2.1.1.3 Power Lights
The two power lights indicate the power status in the Main Power Unit
(MPU), as follows:
Note: The user is prompted to manually remove all the workpieces that are not
properly positioned in the cassette but are situated elsewhere between the
Cassette Compartment and the Cutting Chuck. The workpieces are to be
removed before Stop confirmation.
Figure 2-3: Stop Button Parameters
Note: Power Up the system only after the monitor LED indicator has gone off.