Main Subsystems
Advanced Dicing Technologies Ltd.
2.1-8
a. Open the main workspace Configuration screen.
b. In the value column, next to the parameter Digit I/O, select: Yes.
c. Click Save (see Figure 2-8).
2 Modify the buzzer wiring to accommodate the new feature.
2.1.4 Un-Interruptible Power Supply
The PC Un-Interruptible Power Supply assures that in case of an abnormal
System stopping (such as pressing the Emergency Stop button or in case
of a power failure) the computer still has an independent power input to
shut down properly. The UPS is located inside the system bench.
Figure 2-8: Enabling the Digital I/O PCB
Figure 2-9: UPS
Caution: As long as the UPS is connected to a power source, there is voltage
on its outlet, even if the switch is in OFF position.
Note: If the system is shut down for a long period, it is recommended to
manually turn off the UPS.