Recipe Parameters
Cut Verify Limit Parameters
Advanced Dicing Technologies Ltd.
A-30
Cut Verify Limit Parameters
Table A-11 lists the Cut Verify Limit parameters. The Cut Verify Limit
parameters define limits for the Cut Verification procedure.
Cut Verify X Pos
The position on the X-Axis where Cut Verification is
performed.
This value is automatically specified.
Possible Values:
min = 0, max = 300, Default = 0
Cut Verify X Searches
The number of places for which the machine will
search. These points are taught in the “Teach Align”
procedure.
Cut Verify Y Pos
The position on the Y-Axis where Cut Verification is
performed.
This value is automatically specified.
Possible Values:
min = 0, max = 300, Default = 0
Table A-10: Cut Verify Parameters
Category Parameter Description
Table A-11: Cut Verify Limit Parameters
Category Parameter Description
Cut Verify
Limit
Head1 X-Shift
The maximum shift of the new cut position in the X
direction. Used for Auto Cut Verification.
Possible Values:
min = 0, max = 600, Default = 3
Cut Verify
Limit
Head1 Y-Shift
The maximum shift of the new cut position in the Y
direction. Used for Auto Cut Verification
Possible Values:
min = 0, max = 600, Default = 3
Cut Verify
Limit
Manual Head1
X-Shift
The maximum shift of the new cut position in the X
direction. Used for Manual Cut Verification.
Possible Values:
min = 0, max = 600, Default = 3
Cut Verify
Limit
Manual Head1
Y-Shift
The maximum shift of the new cut position in the Y
direction. Used for Manual Cut Verification.
Possible Values:
min = 0, max = 600, Default = 3