1
Chapter 1 NB04L-02 Configuration
1.1 NB04L-02 standard System
1.1.1 FD-B4L Basic Configuration
Table 1.1.1 NB04L-02 basic configuration
Reference Number
and Parts Name
Model Type Specifications
○
None = Floor-mount
C = Ceiling-mount
W = Wall-mount
① Manipulator
NB04L-02
(Model Type: NB04L-○△-02)
△
None : Except for China and Taiwan
CN = China and Taiwan
For NB04L, NV06L
0
: No External Axis
P : External 1 Axis
2 : External 2 Axes
4 : External 1 Axis x 2
A : Large-capacity External 1 Axis
(Standard Case External Axis Spec.)
② Controller
FD11
(Model Type: FD11–FL 0 ***)
*** : Expansion Case Spec.
1
: Global icons
3 : Icons with Chinese characters
③ Teach pendant
FDTPFSJN-1L**
** : 08 8m Spec. (Standard)
15 15m Spec.
④ Operation Box
(Note 1)
FDOP-00**
** : 05 5m Spec. (Standard)
10 10m Spec.
15 15m Spec.
⑤ Control Cable 1, 3
(Wire Harness)
FDRB-10**
** : 05 5m Spec. (Standard)
10 10m Spec.
15 15m Spec.
(Note 1) In case of not using the operation box, a “connection terminal block” and “selector switch assembly” are required
for mode selection. For details, refer to section 2.2.6 (4).
Fig. 1.1.1 NB04L-02 basic configuration